INSTALLER / CONSUMER
SAFETY INFORMATION
30002008 3/06 Rev. 6
PLEASE READ THIS MANUAL
BEFORE INSTALLING AND USING
APPLIANCE.
WARNING!
IF THE INFORMATION IN THIS
MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING PROPER-
TY DAMAGE, PERSONAL INJURY
OR LOSS OF LIFE.
FOR YOUR SAFETY
Installation and service must be per-
formed by a qualified installer, service
agency or the gas suppler.
WHAT TO DO IF YOU SMELL
GAS:
Do not try to light any appliance.
Do not touch any electric switch; do
not use any phone in your building.
Immediately call your gas supplier
from your neighbors phone. Follow
the gas suppliers instructions.
If you cannot reach your gas supplier,
call the fire department.
DO NOT STORE OR USE GASO-
LINE OR OTHER FLAMMABLE
VAPORS AND LIQUIDS IN THE
VICINITY OF THIS OR ANY OTHER
APPLIANCE.
This appliance may be installed in an
after market permanently located manu-
factured (mobile) home where not pro-
hibited by local codes.
This appliance is only for use with the
type of gas indicated on the rating plate.
This appliance is not convertible for use
with other gases unless a certified kit is
used.
Dutchwest
Natural Vent Gas Heater
Models: 2467, 2468
Homeowners Installation
and Operating Manual
INSTALLER: DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER
CE R TI F IE D
D
E
S
I
G
N
C
E
R
T
I
F
I
E
D
2008
Dutchwest
gas stove
cover
6/03
Page view 0
1 2 3 4 5 6 ... 27 28

Summary of Contents

Page 1 - Dutchwest

INSTALLER / CONSUMER SAFETY INFORMATION30002008 3/06 Rev. 6PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE.WARNING!IF THE INFORMATION

Page 2 - Table of Contents

10Dutchwest Natural Vent Gas Heater30002008Connect the Gas Supply LineCheck the Rating Plate attached by a steel cable to the firebox, to confirm that y

Page 3

11Dutchwest Natural Vent Gas Heater30002008Burner InformationThe appliance must only use the gas specified on the rating plate, unless converted using

Page 4 - 6/23/03

12Dutchwest Natural Vent Gas Heater30002008Install the Stove FrontInsert the handle stub into the hole in the front casting. Fasten in place with the

Page 5 - 5/15/03 djt

13Dutchwest Natural Vent Gas Heater30002008OperationYour First FireRead these instructions carefully and familiarize your-self with the burner control

Page 6

14Dutchwest Natural Vent Gas Heater300020083. Open control access panel.4. Push in gas control knob slightly and turn clock-wise to “OFF”. Do not

Page 7 - Venting Runs

15Dutchwest Natural Vent Gas Heater30002008A. Defective or misaligned Using a match, light [ilot. If pilot lights, turn off pilot andelectrode at the

Page 8 - Install the Optional Fan

16Dutchwest Natural Vent Gas Heater30002008Conversion PrecautionsConversion must be completed only by qualified per-sonnel. Before proceeding, turn con

Page 9 - Venting System Assembly

17Dutchwest Natural Vent Gas Heater30002008CO105agas conversionPilot 1/28/00 djtPilot HoodPilot BracketCO105aFig. 31 Remove pilot hood.CO106a

Page 10 - Connect the Gas Supply Line

18Dutchwest Natural Vent Gas Heater30002008 Conversion to LP Input (BTU/h) Air Shutter Kit # Front Part # Rear Part # Minimum Maximum Setti

Page 11 - 1/31/00 djt

19Dutchwest Natural Vent Gas Heater30002008MaintenanceYour Dutchwest Gas Heater will provide years of service with minimal upkeep. The following proce

Page 12 - 6/6/03

2Dutchwest Natural Vent Gas Heater30002008PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE.Thank you and congratulatio

Page 13 - Operation

20Dutchwest Natural Vent Gas Heater30002008Gasket ReplacementThe Dutchwest Gas Heater uses a ‘tadpole’ type gasket to seal between the glass panel and

Page 14 - Lighting Instructions

21Dutchwest Natural Vent Gas Heater30002008NOTE: IF ANY OF THE ORIGINAL WIRE, AS SUP-PLIED WITH THE APPLIANCE, MUST BE RE-PLACED, IT MUST BE REPLACED

Page 15 - CORRECTIVE ACTION

22Dutchwest Natural Vent Gas Heater30002008Dutchwest Natural Vent Gas Heater Models 2467, 2468 Ref. Description Part Number 1. SDV30 Log Set Asse

Page 16 - Jefferson

23Dutchwest Natural Vent Gas Heater30002008Dutchwest Natural Vent Gas Heater (continued)Models 2467, 2468 Ref. Description Part Number 8. End, Rt

Page 17 - 1/28/00 djt

24Dutchwest Natural Vent Gas Heater30002008Decorative Rings4” brass or black rings are available to add a decorative touch to the exposed stove pipe.

Page 18

25Dutchwest Natural Vent Gas Heater30002008

Page 19 - Maintenance

26Dutchwest Natural Vent Gas Heater30002008

Page 20 - Stove Disassembly

27Dutchwest Natural Vent Gas Heater30002008BASIC WARRANTY CFM Corporation Company (hereinafter referred to collectively as the Company) warrants that

Page 21 - 1/11/00 djt

Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency (%) 2467 51.4 2468 51.42695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N

Page 22 - Models 2467, 2468

3Dutchwest Natural Vent Gas Heater30002008The Dutchwest Natural Vent Room Heater, Model Nos. 2467 and 2468, is a vented gas appliance listed to the

Page 23 - (continued)

4Dutchwest Natural Vent Gas Heater30002008CLValve InletCLValve Inlet2008Dutchwest NVdimensions6/23/03 17"(419 mm)23"(584 mm)28"(72

Page 24 - Remote Controls

5Dutchwest Natural Vent Gas Heater30002008Clearance RequirementsMinimum Clearances to Combustible MaterialsMeasure side clearances as shown in Figures

Page 25 - 30002008

6Dutchwest Natural Vent Gas Heater30002008Venting Requirements and OptionsThe Dutchwest must be properly connected to a listed 4” (102 mm) Type B vent

Page 26

7Dutchwest Natural Vent Gas Heater30002008Passing Through a Combustible Wall or CeilingAn approved pass-through device is always required when a vent

Page 27 - LIMITED LIFETIME WARRANTY

8Dutchwest Natural Vent Gas Heater30002008ST194attach fan to shroud11/99Outer ShroudSlotInner ShroudSlotST194Fig. 11 Position the fan to engage the

Page 28 - CFM Corporation

9Dutchwest Natural Vent Gas Heater30002008ST671attach snapstatSnapstatLeft Air DuctST671Fig. 12 Install the snapstat and connect the extension wire t

Comments to this Manuals

No comments