Homeowner’s Installation and Operating ManualFor use in EuropeDo Not Discard This Manual: Retain for Future Use30003846 4/08 Rev. 1SAFETY NOTICE:
10Defiant 1610CE Non-Catalytic Woodburning Stove30003846Costructional Hearth Dimensions as belowAt least 300 mm At least 150 mm or to a suitable heat
11Defiant 1610CE Non-Catalytic Woodburning Stove30003846Summary of ClearancesMinimum recommended side clearances to non-combustible surfaces 125 mm (5
12Defiant 1610CE Non-Catalytic Woodburning Stove30003846Set Up Your StoveCast iron stoves are heavy, and it will take two to four people to move your
13Defiant 1610CE Non-Catalytic Woodburning Stove30003846Install the Optional Ash Door Heat ShieldMany installations will require the use of the suppli
14Defiant 1610CE Non-Catalytic Woodburning Stove30003846The Defiant Controls Two controls regulate the performance of the Defiant: a primary air contro
15Defiant 1610CE Non-Catalytic Woodburning Stove30003846DefiantST521Intrepidloading11/00ST521Fig. 28 Top loading is the best way to add fuel during r
16Defiant 1610CE Non-Catalytic Woodburning Stove30003846agement information on Page 26 to see how the size, type, and location of your chimney will af
17Defiant 1610CE Non-Catalytic Woodburning Stove30003846ST263starting a fire12/99ST263Fig. 31 Start the fire with newspaper and dry kindling.ST264g
18Defiant 1610CE Non-Catalytic Woodburning Stove30003846operating temperature quickly. Use this sequence as a guide to successful refueling:NOTE: Doo
19Defiant 1610CE Non-Catalytic Woodburning Stove30003846Draft ManagementA stove is part of a system, which includes the chimney, the operator, the fu
2Defiant 1610CE Non-Catalytic Woodburning Stove30003846This manual describes the installation, operation, and maintenance of the Vermont Castings Defia
20Defiant 1610CE Non-Catalytic Woodburning Stove30003846they must turn, it leaves some pipe in the room for heat transfer, and it gives you long-term
21Defiant 1610CE Non-Catalytic Woodburning Stove30003846Below you will find important information on general care, inspection and maintenance of your V
22Defiant 1610CE Non-Catalytic Woodburning Stove30003846Adjust the Damper as NeededThe tension on the Defiant’s damper is adjustable to compensate for
23Defiant 1610CE Non-Catalytic Woodburning Stove300038463. Determine the correct length of the appropriate-sized gasket by laying it out in the channe
24Defiant 1610CE Non-Catalytic Woodburning Stove30003846Clean the chimney connector by disconnecting the sec-tions, taking them outside, and removing
25Defiant 1610CE Non-Catalytic Woodburning Stove300038461287242320221921131451617182569643565678393288424350411548384034253545558767570746880786777757
26Defiant 1610CE Non-Catalytic Woodburning Stove30003846Defiant Woodburning Stove Model 1610CE (continued) 1. Side Insulation 30002846 2. Right Si
27Defiant 1610CE Non-Catalytic Woodburning Stove30003846Defiant Woodburning Stove Model 1610CE (continued) Shell Enamel Parts - Defiant Model 1610CE
LIMITED LIFETIME Warranty For Vermont Castings Defiant, Non-Catalytic Wood StoveLimited Lifetime WarrantyCFM Corporation warrants that all refractory
3Defiant 1610CE Non-Catalytic Woodburning Stove30003846Table of ContentsSpecifications ... 4Installation
4Defiant 1610CE Non-Catalytic Woodburning Stove30003846SpecificationsDefiant, Model 1610CENominal heat output ...14.5 kW (49,500 BTU/hr)1Mnimu
5Defiant 1610CE Non-Catalytic Woodburning Stove30003846InstallationSAFETY NOTICE: IF YOUR DEFIANT IS NOT PROP-ERLY INSTALLED, A HOUSE FIRE MAY RESUL
6Defiant 1610CE Non-Catalytic Woodburning Stove30003846What Kind of Chimney to UseYou must connect the Defiant to a code-approved masonry chimney with
7Defiant 1610CE Non-Catalytic Woodburning Stove30003846c) Mild steel fluepipes complying with BS 1449: Part 1: 1991, with a flue wall thickness of at le
8Defiant 1610CE Non-Catalytic Woodburning Stove30003846securely in place. Most chimney breeches incorporate thimbles, but the fit must be snug and the
9Defiant 1610CE Non-Catalytic Woodburning Stove30003846Through the FireplaceIf your fireplace opening height is at least 737 mm (29"), you may ins