EWF36A
Fireplace
Homeowners
Installation and
Operating Manual
Do Not Discard This Manual: Retain for Future Use
20005167 1/08 Rev. 14
5167
EPA36
cover
3/02
SAFETY NOTICE: IF THIS APPLIANCE IS NOT PROPERLY INSTALLED, OPERATED AND MAIN-
TAINED, A HOUSE FIRE MAY RESULT.
TO REDUCE THE RISK OF FIRE, FOLLOW THE INSTALLATION INSTRUCTIONS. FAILURE TO
FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY OR EVEN
DEATH. CONTACT LOCAL BUILDING OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION
INSPECTION REQUIREMENTS IN YOUR AREA.
Page view 0
1 2 3 4 5 6 ... 31 32

Summary of Contents

Page 1 - Fireplace

EWF36AFireplaceHomeowner’s Installation and Operating ManualDo Not Discard This Manual: Retain for Future Use20005167 1/08 Rev. 145167EPA36cover3/02

Page 2 - Table of Contents

10Vermont Castings EWF36A20005167Ceiling Chimney Hole/ Possible ObstructionsThe size of the hole in ceiling will vary with the angle at which the chim

Page 3 - Safety Information

11Vermont Castings EWF36A20005167Installating Outside Air KitAn outside air kit may be installed on the EWF36A. If desired, or if local codes mandate

Page 4 - Specifications

12Vermont Castings EWF36A20005167Installing the Chimney SystemStart by attaching the first chimney section to the collar on top of the fireplace. Insta

Page 5

13Vermont Castings EWF36A20005167Installing the Firestop Spacer in the Ceiling HoleA firestop spacer is used to keep pipe spaced properly and required

Page 6 - 30˚ Elbow Offsets

14Vermont Castings EWF36A20005167Penetrating the RoofRun pipe to roofline. Since chimney system must be vented to the out-of-doors, you must use an ap

Page 7 - Planning Information

15Vermont Castings EWF36A20005167Finish WallFinish the wall with material of your choice. Do not install a combustible mantel shelf less than 12” (30

Page 8 - Installation

16Vermont Castings EWF36A20005167Examples of wall shield insulation:1. Manville - CERAFORM 126, K=.27, 1/2 inches thick2. EH2416, K = .458, 1 in

Page 9 - 3/20/02 djt

17Vermont Castings EWF36A20005167FP1201Fig. 26 Combustible side wall protection and hearth extension dimensions.Minimum Wall ClearancesWITHNoncombust

Page 10 - 5/13/99 djt

18Vermont Castings EWF36A20005167OperationAttach HandlesThe fallaway handles are used to open and close the front doors. Remove after each use so they

Page 11 - 7/6/00 djt

19Vermont Castings EWF36A20005167KT108bBFCCorrect door position8/23/00 djtKT108bFig. 30 Correct door position during operation.CorrectOptional Spar

Page 12

2Vermont Castings EWF36A20005167IntroductionThank you for purchasing a Vermont Castings, EWF36A fireplace. An efficient fireplace carefully engineered to

Page 13 - 11/20/97

20Vermont Castings EWF36A20005167 Starting and Maintaining a Wood FireBurn solid wood fuel only in the EWF36A, and burn it directly on the grate. Do n

Page 14 - Air Space Clearances

21Vermont Castings EWF36A20005167Different results may be experienced even in the same installation if you switch from burning good, dry wood to wood

Page 15 - Vermont Castings EWF36A

22Vermont Castings EWF36A20005167Keep your EWF36A Fireplace Looking New and Working Its BestCare of the Cast Iron SurfaceAn occasional dusting with a

Page 16 - COMMON MATERIALS AND FACTORS

23Vermont Castings EWF36A20005167When to Suspect a Combustor ProblemThe best way to evaluate the performance of your EWF36A’s combustor is to observe

Page 17 - A B C D E F G H J

24Vermont Castings EWF36A20005167Replaceable Fiberglass Gaskets Gasket Size... ...And The Parts It Seals 1/2” The door to the front 5/8” Door to

Page 18 - Operation

25Vermont Castings EWF36A20005167The prefabricated chimney used with your fireplace should be cleaned from above using an 8” round brush and the approp

Page 19 - 8/23/00 djt

26Vermont Castings EWF36A20005167Chimney Components Component Description Model Number Chimney Support Used to support chimney for each of TCS8

Page 20

27Vermont Castings EWF36A200051671375611464013132022 15861510373647474541441616173952272829303119333435954324243224565552485150497374EWF36CLK757565EWF

Page 21 - Remove and Store Ash Safely

28Vermont Castings EWF36A20005167 22. Glass Right Door - EPA Front 20005152 23. Right, Door Handle Assy. Vert. Nickel 20006286 24. Damper Stee

Page 22 - Maintenance

29Vermont Castings EWF36A20005167Optional AccessoriesFan KitFK26 FanThe FK26 fan helps distribute heated air from within the firebox out into the room.

Page 23 - Assembly out of fireplace

3Vermont Castings EWF36A20005167Safety InformationPlease Read This Manual Before Installing and Using FireplaceIMPORTANT: Read all instructions and wa

Page 24 - The Chimney System

30Vermont Castings EWF36A20005167

Page 25 - Maintenance Schedule

31Vermont Castings EWF36A20005167Warranty Limited 3 Year WarrantyCFM Corporation warrants that this woodburning stove will be free of defects in mater

Page 26 - Chimney Components

2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 • www.cfmcorp.comCFM Corporation

Page 27 - EWF36A Fireplace

4Vermont Castings EWF36A20005167SpecificationsRange of heat output* ... 11,300 - 75,500 Btu/hrMaximum heat output** ... in excess of 100,

Page 28 - (continued)

5Vermont Castings EWF36A20005167Fig. 2 Fireplace and chase parts identification.FP554aFP554aBFCFireplace and chase parts identificationcirculating mod

Page 29 - Fig. 33 FK26 fan placement

6Vermont Castings EWF36A20005167DRiseBGHBOffsetCE6 FT.GHAHearthFloorChimneySectionCHIMNEY FLUE EXITElbowFP269MBUF5/16/96rev. 5/25TCS8A SupportExample

Page 30

7Vermont Castings EWF36A20005167Planning InformationDetermine how the chimney will be run, length of run and chimney components required to complete t

Page 31 - Warranty

8Vermont Castings EWF36A20005167Chimney SupportsThe chimney system is supported by the fireplace for vertical chimney heights less than 30’ (9m) above

Page 32 - CFM Corporation

9Vermont Castings EWF36A20005167FramingFraming can be constructed before or after the fireplace is set in place, however, most installers build the fra