Page view 0
Decorative Gas Appliance
Installation and Homeowners
Operating Instructions
PLEASE READ THIS MANUAL
BEFORE INSTALLING AND USING
APPLIANCE
IMPORTANT: Read all instructions
and warnings carefully before starting
installation. Failure to follow these
instructions may result in a possible
fire hazard and will void the warranty.
WARNING: If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury or loss of life.
FOR YOUR SAFETY
Installation and service must be
performed by a qualified installer,
service agency, or the gas supplier. Do
not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
FOR YOUR SAFETY
If you smell gas:
Do not touch electrical switches.
Do not try to light any appliance.
Do not use the phone in your building.
Immediately call your gas supplier from
a neighbor's phone.
Follow your gas supplier's instructions.
If you cannot reach your gas supplier,
call the fire department.
INSTALLER/CONSUMER
SAFETY INFORMATION
Models: NVC36, NVC39, NVC43
CERT I F I E D
D
E
S
I
G
N
C
E
R
T
I
F
I
E
D
20000194 9/06 Rev. 6
GF461
NVC cover
3/3/97
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Page view 0
1 2 3 4 5 6 ... 27 28

Summary of Contents

Page 1 - Models: NVC36, NVC39, NVC43

Decorative Gas ApplianceInstallation and HomeownersOperating InstructionsPLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCEIMPORTANT: Read

Page 2

10NVC Series B-Vent 20000194Operating InstructionsOnly glass approved by CFM Corporation should be used on this fireplace.• The use of any non-approve

Page 3 - IMPORTANT:

11NVC Series B-Vent200001946. Place the top logs onto the locator notches. Ensure that the logs are secure. (Fig. 12)7. Place ember material. See &quo

Page 4 - Fireplace Dimensions

12NVC Series B-Vent 20000194Test Chimney DrawA "Chimney Draw" test must be made before the instal-lation is complete.1. Close all doors and

Page 5 - DV Builder Front

13NVC Series B-Vent200001943. Open control access panel.4. Push in gas control knob slightly and turn clock-wise to "OFF". Do not force

Page 6 - 1/27/00 djt

14NVC Series B-Vent 20000194Vent Safety SwitchThis fireplace incorporates the use of a Vent Safety Shut-off Switch. The sensor and wiring are factory i

Page 7 - Alternate Switch Location

15NVC Series B-Vent20000194TroubleshootingFP649Turn gas supply offTurn ON/OFF Switchto call for heat.NONONONONONONOSpark acrossIgnitor Sensor gapPower

Page 8 - Flashing and Termination

16NVC Series B-Vent 20000194Remove glass door before service workHoneywell VS8421STARTCHECKGas Supply OnPilot Lights With Piezo Ignitor• Lockout Has

Page 9

17NVC Series B-Vent20000194TroubleshootingFP396Gas Supply OnSupply Line Hooked UpShutoff Valve OpenNONONONOLockout Has Engaged. Wait 60 Seconds and Tr

Page 10 - REMOVE LOUVRE/GRILLE

18NVC Series B-Vent 20000194Cleaning the Standing Pilot Control SystemThe burner and control system consists of • burner tube • gas orifice • pilot

Page 11 - Flame Adjustment

19NVC Series B-Vent20000194FP772AReplacement Parts nvc8/25/98312829266a/b4a/b53635341a1b1c1d1eNVC43 Logs 12737231a1bNVC36 1d1e1c1e1c1a1b1dNVC39 118251

Page 12 - First Firing

2NVC Series B-Vent 20000194Table of ContentsThank you and Congratulations on your purchase of a CFM Corporation fireplace.PLEASE READ THE INSTALLATION

Page 13 - Lighting Instructions

20NVC Series B-Vent 20000194NVC36/39/43 (continued) Ref. Description NVC36 NVC39 NVC43 6a. Orifice Front Burner-Nat. See Rating Plate 6

Page 14 - 11/2/01 djt

21NVC Series B-Vent20000194Optional AccessoriesFan KitsFK12 Fan Assembly1. Open louvre assembly bottom.2. Install FK12 fan in back of unit between

Page 15 - Troubleshooting

22NVC Series B-Vent 20000194Remote ControlsOptional remote control units are available to control different functions of the appliance. Model Functi

Page 16

23NVC Series B-Vent20000194FP1195Arched door front2/27/02 djtFP1196Fig. 28 Arched door front in place.EB-1 Electrical BoxStandard on electronicall

Page 17 - Nova SIT 820 Standing Pilot

24NVC Series B-Vent 20000194

Page 18 - FP392/585

25NVC Series B-Vent20000194

Page 19 - NVC36/39/43

26NVC Series B-Vent 20000194

Page 20 - (continued)

27NVC Series B-Vent20000194BASIC WARRANTY CFM Corporation (hereinafter referred to collectively as the Company) warrants that your new Vermont Castin

Page 21 - Hard (Direct) Wire Hook-Up

2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 • www.cfmcorp.comCFM CorporationEfficiency Ratings Model EnerGuide Ratings

Page 22 - 2/27/02 djt

3NVC Series B-Vent20000194Installation & Operating InstructionsThis gas appliance should be installed by a qualified installer in accordance with l

Page 23

4NVC Series B-Vent 20000194ADNMNABSGHJGas LineAccess - 2" Dia.Gas Line Access 2" Dia. Finished WallThickness6" FlueRough OpeningHeight

Page 24

5NVC Series B-Vent20000194Clearance to CombustiblesAppliances Top ... 0” (0 mm) Bottom ...

Page 25

6NVC Series B-Vent 20000194Gas Specifications1. Choose the unit location. 2. Place the unit into position and sec

Page 26

7NVC Series B-Vent20000194Gas Line InstallationWhen purging gas line the fornt glass must be removed. Purging gas lines must com-ply with ANSI Z223.1/

Page 27 - LIMITED LIFETIME WARRANTY

8NVC Series B-Vent 20000194The fireplace, when installed, must be electrically connected and grounded in accordance with local codes or, in the ab-senc

Page 28 - CFM Corporation

9NVC Series B-Vent20000194Fig. 9 Firestop/draftstop positions.Ceiling InstallationFP384 FIRESTOP11/21/96adapted from IGF53Attic InstallationFirest